Tube size range round or square 20-2000 mm
Resolution 0.01 mm up to 500 mm (0. 1mm above 500 mm)
Measurement rate for a complete profile 200 ms
Repeatability for averaged numerical values ± 0.1 mm at 2σ
Number of lasers (min & max) 8-24
Laser measurement rate 2000 (Hz)
Lifting table travel ± 50 mm
Cooling air 2500 (m³/h)
Cooling air temperature 10-30 (°C)
Inner diameter 550 mm (depending on model)
Overall dimensions 2000 (h) x 1700 (w) x  600 (l)
Electrical power requirements 230 VAC, 50Hz, 16A or 120VAC, 60 Hz)