| Performance | |
| Measuring range (direct to object)* ¹ | 30 m (98ft) |
| Measuring range (reflective target)* ¹ | 100 m (328ft) |
| Measuring accuracy*² | ±3mm ( 15°C to 30°C)±5mm (-10°C to 50°C) |
| Measuring resolution | 0.1 mm |
| Repeatability | ≤0.5 mm |
| Measuring rate | 0.02 to 6 seconds |
| Interfaces | |
| Serial (2400-38,400 bit/sec) | RS232 (XLR30.1) or Serial RS422 (XLR30.2) |
| Analogue | 4-20 mA user programmable range |
| Profibus / SSI | XLR30.3 version only |
| Trigger input | Trigger edge and trigger delay, adjustable |
| General | |
| Laser class | Class 2, ≤ 1mW power, 650 nm visible |
| Operating temperature | -10°C to 60°C |
| Protection class | IP65 |
| Dimensions (L x W x H) | 212 x 96 x 50 mm |
| Supply voltage | 10-30 VDC |
*¹Dependant on target reflectivity, stray light influences and atmospheric
conditions
*²statistical spread 95%