Product
XLR30 - Specification
|
Performance |
|
|
Measuring range (direct to object)* ¹ |
30 m (98ft) |
|
Measuring range (reflective target)* ¹ |
100 m (328ft) |
|
Measuring accuracy*² |
±3mm ( 15°C to 30°C) ±5mm (-10°C to 50°C) |
|
Measuring resolution (max) |
0.1 mm |
|
Repeatability |
≤0.5 mm |
|
Measuring rate |
0.02 to 6 seconds |
|
Interfaces |
|
|
Serial (2400-38,400 bit/sec) |
RS232 (XLR30.1) or Serial RS422 (XLR30.2) |
|
Analogue |
4-20 mA user programmable range |
|
Profibus |
XLR30.3 version only |
|
Trigger input |
Trigger edge and trigger delay, adjustable |
|
General |
|
|
Laser class |
Class 2, ≤ 1mW power, 650 nm visible |
|
Operating temperature |
-10°C to 60°C |
|
Protection class |
IP65 |
|
Dimensions (L x W x H) |
212 x 96 x 50 mm |
|
Supply voltage |
10-30 VDC |
*¹Dependant on target reflectivity, stray light influences and atmospheric conditions
*²statistical spread 95%