Impac® Series 600 Pyrometers

Customisable Modular Multi-sensor Pyrometers

The Impac® Series 600 is a customisable modular multi-sensor head pyrometer suitable for measuring temperature in the range of -40°C to 700°C for non-metallic applications.

 

 

The sensor configuration can be easily customised by using different combinations of the following system components:

    • Converter Box
    • Sensor Heads
    • Multi Box

The converter box can be connected to up to sensor heads or up to two optional multi boxes that connect to up to four sensor heads each, meaning that it is possible to use up to eight sensor heads for measuring temperature in eight separate measuring locations with a single converter box.  The sensor heads are available in three different optics, with the field of view 2:1, 10:1 or 20:1 and a single system can have a combination of different sensors heads.

Customisable Modular Multi-sensor Pyrometers

The Impac® Series 600 is easy to install, use and maintain. The modular concept and compact pyrometer heads of only 14mm diameter allow temperature measurement in multiple locations, even where space is restricted. The pyrometers are supplied with Windows Infra600 software, that allows configuration and graphing of up to eight channels simultaneously. Damaged sensor heads can be easily replaced without having to replace the entire cable, reducing maintenance costs and increasing uptime.

Possible Applications:

  • Automotive
  • Laminating
  • Injection Moulding
  • PET bottles
  • Plastics
  • Packaging/Converting
  • Paper/Coating

Converter Box Dimensions

Customisable Modular Multi-sensor Pyrometer Customisable Modular Multi-sensor Pyrometer

Sensor Head Dimensions

Multi Box Dimensions

Technical Specifications

Temperature Range  -40°C to 700°C (Subrange: Adjustable; minimum range 51°C)
Spectral Range IN 600 Sensor Heads: 8 to 14 µm
Measurement Uncertainty 0 to 700°C: 0.7% of reading in °C or 1°C
Optics  Three fixed optics with Distance Ratio 2:1, 10:1 or 20:1
Analog Output  Linear current (0 or 4 to 20 mA), voltage (0 to 5 V) or thermocouple (type J or K)
Digital Interface Switchable RS-232 and RS-485 (optional)
Ambient Temperature Converter, analogue box, USB sensor heads: 0 to 65°C
Sensor head (IN 600), multi-sensor box, sensor cables: 0 to 80°C
Power Supply 5 VDC (when connected via USB) or 10 to 30 VDC